Inquiry
Form loading...
Trusyou Implant System Clinical Cases Phase 1

Learning Center

Trusyou Implant System Clinical Cases Phase 1

Patient information:

History of current illness: The patient's lower left first molar suffered pain due to deep caries many years ago, and was subsequently extracted without repair. She found it inconvenient to chew food, so she came to our hospital for repair. After consideration by the patient, the implant restoration plan was finally chosen.

Past history: The patient reported previous physical examinations and found no history of high blood pressure, heart disease, diabetes, or infectious diseases such as hepatitis and tuberculosis or close contact history. There was no history of major trauma or surgery, and no history of blood transfusion. There was no history of drug or food allergies, vaccinations were carried out locally, and no obvious abnormalities were found in the rest of the system review. He has a history of smoking, about 10 cigarettes/day. Drink a small amount of alcohol.

Physical examination: Height: 1.70 m Weight: 69.0 KG

T: 36.7℃ P: 77 times/min R: 18 times/min

BP: 120/80 mmHg

Condition of opposing jaw teeth: normal; condition of mesial and distal adjacent teeth: normal

Example 1 of short-term clinical comparative observation of Excellent implants applied to dentition defects

Patient Information:

Name: Zhou
Gender: Male
Contributor: myself
Age:36
Marriage:married
Record date:2012/10/24

Main complaint: The left lower back tooth has been missing for many years and now requires restoration.

History of current illness: The patient's lower left first molar suffered pain due to deep caries many years ago, and was subsequently extracted without repair. She found it inconvenient to chew food, so she came to our hospital for repair. After consideration by the patient, the implant restoration plan was finally chosen.

Past history: The patient reported previous physical examinations and found no history of high blood pressure, heart disease, diabetes, hepatitis, tuberculosis and other infectious diseases and no history of close contact with them. There was no history of major trauma or surgery and no history of blood transfusion. There was no history of drug or food allergies, vaccinations were carried out locally, and no obvious abnormalities were found in the rest of the system review. He has a history of smoking, about 10 cigarettes/day. Drink a small amount of alcohol.

Physical examination: 
Height: 1.70 m 
Weight: 69.0KG 
T: 36.7°C
P: 77 times/min 
R: 18 times/min 
BP: 120/80 mmHg
Condition of opposing jaw teeth: normal
Condition of mesial and distal adjacent teeth: normal

Diagnosis: 36 missing
Treatment plan: 36 implants of Truysou implants

Preoperative imaging:

Deep coverage , bite tight
37Mesial tilt , Moderate smoking history
A small amount of vertical bone resorption at the edentulous site

Zhuo Shiyou Implant System Clinical Cases Phase 1 (4).png

Operation situation:

BL.RC4112 implant placement
Surgery date: 2012/11/05

Intraoperative observations:
Vital signs: T: 36.7℃, P: 082 times/min, R: 20 times/min, BP: 120/85 mmHg
Type of disinfectant: iodophor
Anesthesia method: infiltration anesthesia
Incision method: I-shaped incision

Postoperative records:
Implantation sites: 36
Implantation site bone quality: Class III bone
Bone mass evaluation at the implant site: A small amount of vertical resorption of alveolar bone
Implant model: BL.RC4112, Ф4.1, L=12
Healing cap: BL.HA.RC6020, Ф6.0, H=2
Whether to use bone grafting: No
Implantation method: non-embedded
Implant stability: good
Suture condition: interrupted suture
Postoperative medication: Cefadroxil 0.25q times/2/day, 3 days
Imaging examination: The implant direction and position of 36 implants are good.
Postoperative doctor's instructions: pay attention to oral hygiene maintenance, follow up with follow-up consultations on time, and follow up if any discomfort occurs.

Postoperative imaging:

The implant is in good three-dimensional position
Sufficient bite clearance
The first threaded bone height is 2.8mm
Initial stability>35N

Zhuo Shiyou Implant System Clinical Cases Phase 1 (3).png

Restoration of images (14 weeks):
Good implant stability
There is no abnormality around the implant. The first thread bone height is 2.6mm.
Ф3.5  , H=5   , BL.TA.5    NC3520
Adhesive repair and repair, follow-up visit after three months/half a year
No obvious abnormality found

Zhuo Shiyou Implant System Clinical Cases Phase 1 (1).png

Images five years after restoration:
Good implant stability
No abnormalities around the implant
The first threaded bone height is 2.2mm
The prosthetic crown is well used

Zhuo Shiyou Implant System Clinical Cases Phase 1 (2).png

Author introduction:
Tong Xin
Department: Department of Oral Implantology, Stomatological Hospital Affiliated to Nanjing University School of Medicine
Professional title: Chief Physician, Associate Professor, Master Tutor, Director of Oral Implantology Department